Size of Concrete Block1900 mmx2200 mmx1000 mm
Foundation Pit Size2100 mmx2400mmx1100 mm
Foundation Isolation SolutionDynemech's Foundation
Insulation Sheet75 mm thick
Measuring Range700/1000/600 mm
BrandDynemech
Weight1550 Kg

Owing to our expertise, we are introducing a broad array of Foundation Isolation - Zeiss CMM. The offered product range is designed with the aid of latest techniques by our professionals in compliance with the market standards. Extensively admired among customers all across the globe, this product range is provided in numerous specifications to choose from. Our honored customers can take this product range in different sizes at reasonable prices.

Features:
  • Sturdy construction
  • Excellent efficiency
  • Less maintenance

 

Guide Lines:

  • Pit should be 100% water proof; check ground water conditions.
  • The inner surface of the pit should be clean, dry & smooth.
  • As per the detailed layout supplied by Dynemech, place vibration damping plate set Dp Paste them to the pit base using – Pidlite SR-505 adhesive.
  • Place filler foam in the gaps between the Insulation plate set Dp. Paste them to the pit surface.
  • Place PVC on the entire pit surface and side walls. Seal the overlapping joints of the PVC sheet with adhesive tape so that the concrete water should not leak in to the pit base.
  • Place 25mm thick wooden board layer and joint should be sealed with adhesive tape. This will act as a support for the initial concrete pour.
  • Place another layer of PVC sheet on the pit base and the side walls joints sealed with adhesive tape.
  • Pour concrete up to a depth of 150mmand allow it to dry, this will act as a compression plate. After drying the compression plate erect reinforcement and pour concrete in the rest of the concrete block volume. Concrete should be poured in layers of 300mm+300mm+350mm to complete a depth of 1100mm, allow each layer to dry and pour another layer.
  • The concrete block and the pit tub should not come in contact with each other.
  • Care should be taken that the concrete or concrete laced water should not leak in to the insulation plate area.
  • The side gaps may be filled with rubberised cork scrap.


    Additional Information:

    • Item Code: Zeiss-CMM
    Yes! I am interested

    View PDF

    Passive Vibration Isolation

    REQUEST CALLBACK

    Passive Vibration Isolation
    • Passive Vibration Isolation
    • Passive Vibration Isolation
    Ask for Price

    Thanks for Contacting Us.

    Product Price :Get Latest Price

    Product Details:
    ColorBlack
    UsageIndustrial
    Load Capacity200-700 Kg
    BrandDynemech
    MaterialCarbon Steel

    Isolated foundation for active vibration damping for power presses, forging hammers, engine test rigs, and passive vibration isolation of machining centres, grinding machines, measuring & testing equipments, laser cutters and microscopes.

    The Isolated Foundation is required to reduce both active and passive vibrations. Vibration isolation mountings are required to reduce the transmission of vibration and shocks.
    A foundation block or Vibration isolation mountings for high dynamic machines like power press, forging hammers, compressors, engine test rigs etc. is required in order to reduce the transmission of vibration and shock to nearby precision machines / building structures. To control the source of vibration disturbance through the use of resilient insulating materials is known as ACTIVE VIBRATION ISOLATION.

    When it is not possible to prevent or sufficiently lower the transmission of shock and vibration from the source, a resiliently supported vibration insulating foundation block can be used for the PASSIVE VIBRATION ISOLATION of sensitive equipments like Machining Centres, Measuring and Testing Machines / Equipments etc.

    Isolated Foundation lowers the centre of gravity of the machine foundation system and adds to the stability of the machine. Machine remains aligned during dynamic load changes and rapid movements within the machines.
    Yes! I am interested

    View PDF
     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Dynemech Systems Private Limited
    Yogesh Bansal (General Manager)
    Plot No. 136, HSIIDC, Rai Industrial Area , Rohini Sector 14,
    Sonipat - 131029, Haryana, India
    Call Us: 
    Call Response Rate: 94%
    Share Us :
    F G T L



    Home  |   Profile   |  Products We Offer  |  Site Map  |   Contact Us   |   Mobile Site

    © Dynemech Systems Private Limited. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Dynemech Systems Private Limited